| UNITED
STATES TESTING COMPANY 5555 Telegraph Road Los Angeles, CA 90040 Member of the SGS Group (societe Generale de Surveillance) Test report numbers: 720001-1, 2, 2R, 3, 4June 1, 1995 |
| ASTM TEST REFERENCE/EQUIV. | TEST DESCRIPTION | RATING/RESULT | NOTES/CODES CITED | |
| ASTM
E-648-93a NFPA No. 253 |
CRITICAL RADIANT HEAT FLUX (RADIANT PANEL) | CLASS I (MIN. 0.45 WATTS PER SQ.CM.) | ALL
SPECIMENS MET EXCEEDED THE 4.5 MINIMUM. SUITABLE FOR USE IN HEALTH CARE CENTERS, CHILD CARE CENTERS, HOTELS, DORMITORIES AND APARTMENTS. COMPARE TO 0.48 WATTS (CLASS II) REPORTED BY LEADING OAK MANUFACTURER. |
|
| ASTM
E-84-91a ANSVNFPA No. 255 UBC No. 8-1 UL No. 723 |
FLAME
SPREAD/SMOKE DENSITY |
NFPA
CLASS C UBC CLASS III FLAME SPREAD: 110 SMOKE DENSITY: 135 |
LIFE
SAFETY CODE, 1994; NATIONAL FIRE PROTECTION ASSOCIATION, ANSVNFPA NO. 101; UNIFORM BUILDING CODE, 1984 EDITION, CHAPTER 8 SEC. 801-807 |
|
| ASTM
E-662-93 NFPA No. 258 |
SMOKE
DENSITY NBS CHAMBER (SPECIFIC OPTICAL DENSITY OF SMOKE GENERATED) |
FLAMING:
UNDER 150 NON-FLAMING: UNDER 280 |
NON-FLAMING
MODE RESULTS CONSIDERABLY LOWER THAN LEADING OAK MANUFACTURER |
| ASTM D-4060-90 | FALLING
SAND ABRASION (METHOD OF MEASURING ABRASION RESISTANCE OF ORGANIC COATINGS) |
WEAR
INDEX: 9MIL 4,250 CYCLES WERE REQUIRED TO REMOVE COATING. |
RECOMMENDED FOR ALL RESIDENTIAL & LIGHT COMMERCIAL APPLICATIONS INCLUDING HIGH TRAFFIC AREAS. COMPARE TO 11 MIL IN LEADING OAK MANUFACTURES PUBLISHED LITERATURE | |
| ASTM E-968-93 | FALLING
SAND ABRASION (METHOD OF MEASURING ABRASION RESISTANCE OF ORGANIC COATINGS) AMOUNT OF ABRASIVE NEEDED TO REMOVE 1 MIL OF COATING |
>250,000 MILLILITERS | TEST WAS STOPPED AFTER 250,000 MILLILITERS OF ABRASIVE SAND FAILED TO REMOVE EVEN 1 MIL OF FINISH COATING. COMPARE WITH 68,000 MILLILITERS TO REMOVE 1 MIL OF FINISH IN LEADING UV CURED URETHANE OAK PRODUCT AND WITH 45,000 MILLILITERS TO REMOVE 1 MIL OF FINISH FROM OTHER COMPETITIVE URETHANE FINISHED FLOORING | |
| ASTM
D-2394-83 (1993) SEC. 33-37 |
COEFFICIENT OF FRICTION (SLIP RESISTANCE) (METHOD FOR SIMULATED SERVICE TESTING) | LOW
GLOSS: 590 SEMI GLOSS: 370 |
STATIC COEFFICIENT OF .590 EXCEEDS THE OSHA RECOMMENDATION FOR LEVEL SURFACES IN THE WORKPLACE | |
| ASTM
D-2394-83 (1993) SEC 18-22 |
HARDNESS (METHOD OF MEASURING HARDNESS ACCORDING TO THE INDENTATION CAUSED BY A FALLING BALL) | 27 MIL | C.K. BAMBOO FLOORING SHOWED EXCELLENT HARDNESS WHEN A 2.0 INCH DIAMETER STELL BALL WEIGHTING 1.18 LBS AND DROPPED FROM A HEIGHT OF 6 FEET CAUSED AN INDENTATION OF ONLY 27 MIL. |
| DESCRIPTION | STANDARD | RESULT | |
| SPECIFIC GRAVITY | Wa/Va | 0.81% | |
| MOISTURE CONTENT | % | 10.5 | |
| STATIC
BENDING STRENGTH KGF/SQ.CM |
MODULUS OF RUPTURE | 1247 | |
| STATIC
BENDING STRENGTH KGF/SQ.CM |
MODULUS OF ELASTICITY | 124820 | |
| IMPACT ABSORPTION ENERGY | KGF/SQ. CM | 1012 | |
| SHEARING STRENGTH | KGF/SQ. CM | 136 | |
| HARDNESS IN LONGITUDINAL | KGF/SQ. CM | 5.32 |